STRUCTURE:
* Mono copper conductor, * PVC insulation
CODE:
*H05V-U, H07V-U (NYA) ◄HAR► *H05V-U : 300/500 V
STANDARDS:
TS 9758 (HD 21.3.S3), VDE 0281, IEC 60227, BS 6004
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 300 / 500 V & 450 / 750 V
AC Test voltage: 2000 V - 2500 V
USED PLACES:
It is used in closed and dry areas, control panels, fixed installations in cable ducts and pipes.
STRUCTURE:
* Stranded copper conductor, * PVC insulation
CODE:
H07V-R (NYA) ◄HAR►
STANDARDS:
TS 9758 (HD 21.3.S3), VDE 0281, IEC 60227, BS 6004
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec) Rated voltage: 450 / 750 V
AC Test voltage: 2500 V
USED PLACES:
It is used in closed and dry areas, control panels, fixed installations in cable ducts and pipes.
STRUCTURE:
* Fine stranded copper conductor, * PVC insulation
CODE:
H05V-K, H07V-K (NYA-F) ◄HAR► *H05V-U : 300/500 V
STANDARDS:
TS 9758 (HD 21.3.S3), VDE 0281, IEC 60227, BS 6004
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 300 / 500 V & 450 / 750 V
AC Test voltage: 2000 V - 2500 V
USED PLACES:
It is used in the connections of mobile devices, in closed and dry areas, in cable ducts and pipes on and under plaster.
STRUCTURE:
* Single or stranded twisted copper conductor, * PVC insulation, * PVC filling, * PVC outer sheath
CODE:
NYM, 05VV-U, 05VV-R, CU/PVC/PVC (NVV)
STANDARDS:
TS 9758 (HD 21.4.S2), VDE 0250, IEC 60227, BS 6004
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 300 / 500 V
AC Test voltage: 2000 V
USED PLACES:
It is used on and under plaster in damp places and closed areas where there is no mechanical stress.
STRUCTURE:
* Fine stranded twisted copper conductor, * PVC insulation, * PVC outer sheath
CODE:
*H03VV-F, H05VV-F, NYMHY-rd, (FFV-n) ◄HAR► *H05V-U : 300/500 V
STANDARDS:
TS 9760 (HD 21.5.S3), VDE 0250, IEC 60227, BS 6500
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 300 / 300 V, 300 / 500 V
AC Test voltage: 2000 V
USED PLACES:
It is used in mobile device connections, in closed, dry, humid, steamy environments where movement-based mechanical stresses exist, and in electrical household appliances.
STRUCTURE:
* Fine stranded twisted copper conductor, * PVC insulation, * PVC outer sheath
CODE:
*H05VVH6-F
H07VVH6-F
STANDARDS:
TS 9761 TS IEC 60227-6 TS EN 50214
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: *H05VVH6-F 300 / 500 V : H07VVH6-F 450 / 750 V
AC Test voltage: 2000 V - 2500 V
USED PLACES:
flat cables; They are preferred in carrier and lifting equipment such as elevators and cranes, in the parts of planar moving machines subject to fast and hard bending, due to their small bending diameter, small footprint and high flexibility propertpan>
STRUCTURE:
* Single or stranded twisted copper conductor, * PVC insulation, * PVC outer sheath
CODE:
YVV, Cu/PVC/PVC (NYY)
STANDARDS:
TS IEC 60502-1, VDE 0276, IEC 60502, BS 6346
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature Cross section < 300 mm² : 160 °C (t≤5 sec) Cross section > 300 mm² : 140 °C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in places where there is no mechanical stress, in energy networks, as a lighting cable indoors and outdoors, underground and in cable ducts.
STRUCTURE:
* Single or stranded twisted copper conductor, * PVC insulation, * PVC filling, * PVC outer sheath
CODE:
YVV, Cu/PVC/PVC (NYY)
STANDARDS:
TS IEC 60502-1, VDE 0276, IEC 60502, BS 6346
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in places where there is no mechanical stress, in energy networks, as a lighting cable indoors and outdoors, underground and in cable ducts.
STRUCTURE:
* Single or stranded twisted copper conductor, * PVC insulation, * PVC filling, * PVC outer sheath
CODE:
YVV, Cu/PVC/PVC (NYY)
STANDARDS:
TS IEC 60502-1, VDE 0276, IEC 60502, BS 6346
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in places where there is no mechanical stress, in energy networks, as a lighting cable indoors and outdoors, underground and in cable ducts.
STRUCTURE:
* Stranded stranded copper conductor, * PVC insulation, * PVC filling, * PVC outer sheath
CODE:
YVV, Cu/PVC/PVC (NYY)
STANDARDS:
TS IEC 60502-1, VDE 0276, IEC 60502, BS 6346
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in places where there is no mechanical stress, in energy networks, as a lighting cable indoors and outdoors, underground and in cable ducts.
STRUCTURE:
* Single or stranded twisted copper conductor, * PVC insulation, * PVC filling, * PVC outer sheath
CODE:
YVV, Cu/PVC/PVC (NYY)
STANDARDS:
TS IEC 60502-1, VDE 0276, IEC 60502, BS 6346
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in places where there is no mechanical stress, in energy networks, as a lighting cable indoors and outdoors, underground and in cable ducts.
STRUCTURE:
* Single or stranded twisted copper conductor, * PVC insulation, * PVC filling, * PVC outer sheath
CODE:
YVV, Cu/PVC/PVC (NYY)
STANDARDS:
TS IEC 60502-1, VDE 0276, IEC 60502, BS 6346
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in places where there is no mechanical stress, in energy networks, as a lighting cable indoors and outdoors, underground and in cable ducts.
STRUCTURE:
* Single or stranded twisted copper conductor, * PVC insulation, * PVC separating sheath, * Concentric conductor, * Holding copper tape, * PVC outer sheath
CODE:
YVC7V (NYCY)
STANDARDS:
TS IEC 60502-1, VDE 0276, IEC 60502
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
These cables, which are used in industry, switchgear facilities and city networks, are different from other cables, by using the very fast information transfer feature of the concentric conductor, which is under the outer sheath in their structure, to the energy protection systems, by sensing the mechanical impacts coming from the outside to the cable, and sending information very quickly to the protection systems of the network it supplies power to. By activating the protection systems, it ensures that the system it powers is protected from all kinds of damage.
STRUCTURE:
* Single or stranded twisted copper conductor, * PVC insulation, * PVC separator sheath, * PVC outer sheath, * Galvanized round steel wire armor
CODE:
YVZ2V, Cu/PVC/SWA/PVC (NYRY)
STANDARDS:
TS IEC 60502-1, VDE 0271, IEC 60502
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in power centers, switchgear and industrial facilities, as a power cable in local energy distribution, indoor and outdoor areas, direct underground applications and heavy operating conditions. It can be used in fresh and salt water as a result of special production.
STRUCTURE:
* Stranded copper conductor, * PVC insulation, * PVC separator sheath, * Galvanized flat steel wire armor, * Galvanized holding steel tape, * PVC outer sheath
CODE:
YVZ3V, Cu/PVC/SWA/PVC (NYFGbY)
STANDARDS:
TS IEC 60502-1, VDE 0271, IEC 60502
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in power centers, switchgear and industrial facilities, as a power cable in local energy distribution, indoor and outdoor areas, direct underground applications and heavy operating conditions. It can be used in fresh and salt water as a result of special production.
STRUCTURE:
* Stranded copper conductor, * PVC insulation, * PVC separator sheath, * Galvanized flat steel wire armor, * Galvanized holding steel tape, * PVC outer sheath
CODE:
YVZ3V, Cu/PVC/SWA/PVC (NYFGbY)
STANDARDS:
TS IEC 60502-1, VDE 0271, IEC 60502
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in power centers, switchgear and industrial facilities, as a power cable in local energy distribution, indoor and outdoor areas, direct underground applications and heavy operating conditions. It can be used in fresh and salt water as a result of special production.
STRUCTURE:
* Stranded copper conductor, * PVC insulation, * PVC separate sheath, * Galvanized round steel wire armor, * PVC outer sheath
CODE:
YVZ2V, Cu/PVC/SWA/PVC (NYRY)
STANDARDS:
TS IEC 60502-1, VDE 0271, IEC 60502
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in power centers, switchgear and industrial facilities, as a power cable in local energy distribution, indoor and outdoor areas, direct underground applications and heavy operating conditions. It can be used in fresh and salt water as a result of special production.
STRUCTURE:
* Single or stranded copper conductor, * PVC insulation, * PVC separator sheath, * Galvanized round steel wire armor, * PVC outer sheath
CODE:
YVZ2V, Cu/PVC/SWA/PVC (NYRY)
STANDARDS:
TS IEC 60502-1, VDE 0271, IEC 60502
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in power centers, switchgear and industrial facilities, as a power cable in local energy distribution, indoor and outdoor areas, direct underground applications and heavy operating conditions. It can be used in fresh and salt water as a result of special production.
STRUCTURE:
* Stranded copper conductor, * PVC insulation, * PVC separator sheath, * Galvanized flat steel wire armor, * Galvanized holding steel tape, * PVC outer sheath
CODE:
YVZ3V, Cu/PVC/SWA/PVC (NYFGbY)
STANDARDS:
TS IEC 60502-1, VDE 0271, IEC 60502
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in power centers, switchgear and industrial facilities, as a power cable in local energy distribution, indoor and outdoor areas, direct underground applications and heavy operating conditions. It can be used in fresh and salt water as a result of special production.
STRUCTURE:
* Stranded copper conductor, * PVC insulation, * PVC separator sheath, * Galvanized double steel tape armor, * PVC outer sheath
CODE:
YVZ4V, Cu/PVC/SWA/PVC (NYBY)
STANDARDS:
TS IEC 60502-1, VDE 0271, IEC 60502
TECHNICAL VALUES:
Max. operating temperature : 70° C
Max. short circuit temperature : 160° C (t≤5 sec)
Rated voltage: 0.6 / 1 kV
AC Test voltage : 3,5 kV
USED PLACES:
It is used in power centers, switchgear and industrial facilities, as a power cable in local energy distribution, indoor and outdoor areas, direct underground applications and heavy operating conditions. It can be used in fresh and salt water as a result of special production.